RAP-I-FORM
Installation Instructions
| 1.
Chalk building line on footing
2.
Place clips on building line.
3.
Set panels A & B and secure at corner. Then set
panels C, D, & E, and continue along building line,
making sure to place clips top and bottom 4-8”
from end of each panel as shown. If desired, clips on
joints may be nailed after placement of panel. (Exact
spacing is not necessary.)
Caution:
Always make certain there is a clip to hold the end
of each panel regardless of where the panel joint may
be.
Prenailing
of clips: This will cause incorrect
spacing and loss of time.
Note:
With the RAP-I-FORM® system a level footing is not
necessary, however, a flat footing surface will speed
the form setting process and simplify alignment of the
panels.
It is also imperative
that the form clip be fully engaged to the bottom of
the panel. An un-level footing could allow the form
clip to drop below the edge of the panel restricting
the ability of the form clip to capture the form panel.
To correct the form clip alignment, nail form clip securely
to the bottom of the form panel. |

W
= Wall Thickness
P = Panel Thickness

|

1.
Footing forms in position using RAP-I-FORM®
Clips & Stakes
|

2.
RAP-I-FORM® Clips placed
on building line, ready to set panels. Nail corner
clips
|
| |
|

3.
Panel held by RAP-I-FORM®
clips top and bottom, ready for grade, final alignment
check and pouring concrete.
|

4.
Proper clip spacing on joint, showing natural off-set
of panel from corner start. Use same spacing top and
bottom.
|
| |
|

5.
Sheet metal pan held in place by RAP-I-FORM®
clips. Pan eliminates cutting of inside panels and
provides starting point for stripping.
|

It's
That Easy!
|
2000#
TIE SPACING*
These tables are based on Hand
Spading of Concrete; if mechanical vibration is used, decrease
rate of pour or increase number of ties.
| A |
2
Ft |
3
Ft |
4
Ft |
5
Ft. |
6
Ft. |
8
Ft. |
2
Ft. |
3
Ft. |
4
Ft. |
5
Ft. |
6
Ft. |
8
Ft. |
| B |
450# |
600# |
750# |
900# |
1050# |
1350# |
350# |
450# |
550# |
650# |
750# |
950# |
| C |
24" |
20" |
16" |
14" |
12" |
12" |
24" |
20" |
18" |
16" |
12" |
12" |
| A = Rate
of pour foot of height per hour |
B = Concrete Pressure
per sq. ft. of form |
C = Tie Spacing |
*Note: The
tie spacings listed are the maximum permissible spacings for
the listed temperatures and rates of pour. RAP-I-FORM®
shall not be responsible or liable for form failures where
maximum Tie Spacing or recommended rate of pour listed above
has been exceeded.
Wall
& Panel Chart
RAP-I-FORM®
clips are available for virtually any wall thickness and can
be used with either plywood or dimension lumber. The table
below shows the most common combinations of wall and panel
thicknesses which are stocked for immediate shipment.
|
Stocked
For Immediate Shipment |
Maximum
Clip Spacing |
W.
Wall Thickness |
P.
Panel Thickness
|
Pours
to 24" Height |
Pours
to 32" Height |
4" |
3/4"
|
1-1/8" |
- |
- |
24"
MAX |
32"
MAX |
5-5/8" |
- |
1-1/8" |
- |
- |
" |
" |
6" |
3/4" |
1-1/8" |
1-5/8" |
- |
" |
" |
7-5/8" |
3/4" |
1-1/8" |
1-5/8" |
2-1/4" |
" |
" |
8" |
3/4" |
1-1/8" |
1-5/8" |
2-1/4" |
" |
" |
9" |
3/4" |
1-1/8" |
1-5/8" |
2-1/4" |
" |
" |
10" |
3/4" |
1-1/8" |
1-5/8" |
2-1/4" |
" |
" |
11-5/8" |
3/4" |
1-1/8" |
- |
2-1/4" |
" |
" |
12" |
3/4" |
1-1/8" |
1-5/8" |
2-1/4" |
" |
" |
14" |
3/4" |
1-1/8" |
1-5/8" |
- |
" |
- |
15" |
3/4" |
1-1/8" |
1-5/8" |
- |
" |
- |
16" |
3/4" |
1-1/8" |
1-5/8" |
- |
" |
- |
3/4" and 1-1/8"
panel size is for reversible plywood panels.
1-5/8" size is for
dimensional lumber.
2-1/4" size is for
5/8" plywood on a 2 x 4 frame.
RAP-I-FORM®
shall not be responsible or liable for form failures where
maximum clip spacing or recommended rate of pour has been
exceeded. The clip spacings and rates of pour listed are the
maximum permissible for each size clip.
RAP-I-FACTS!
The
initial cost of RAP-I-FORM® forming system is 50% less
than competitive systems when used with 1-1/8" HDO plywood.
The RAP-I-FORM® system eliminated the need to drill panels,
fabricate inside and outside corners, or the labor of handling
forming lumber such as walers and base plates.

For
a U.S.A. or Canadian RAP-I-FORM®
Distributor:
|